TPI 717R Kit 5 Flue Gas Analyser Kit

Rating:
80% of 100

£579.95

£695.94

SKU
TPI/717R-KIT5
  • Multi Fuel as Standard
  • Long life warranty - 6 Years providing peace of mind
  • High Capacity Sensors - 10,000 PPM CO as standard
  • Fixed Service Costs
pdf
(Size: 218.4 KB)
pdf
(Size: 2 MB)
More Information
Warranty 6 years
Price Match No

TPI 7171R Kit 5 Flue Gas Analyser Kit

New Flue gas analyser from the respected TPI range. Versatile and economic. 717R offer ease of use together with a range of features to assist the heating engineer.

The 717R features menu driven software which can supply reports both on screen and via the optional infra-red linked printer. Functions include: Flue gas analysis, differential temperature, differential pressure and room CO safety testing.

Building on the tried and tested 709R, the 717R also features timed tightness/let-by testing and timed CO room build-up testing. Additionally, the analyser serial number and calibration date can be included on printed reports for verification.

TPI's most comprehensive 717R kit. This bundle pack comes with a flue gas analyser, all standard accessories and a pack including an infrared printer, 2 x pipe clamp temperature probes, a CPA1 cooker probe kit and a TPI 719 Gas Sniffer.

Packed full of features, the 717R is a must-have for any gas professional. It is compatible with a wide variety of different fuel types and can be used to make sure every boiler you install, commision or maintain is in line with all regulations.

The 717R has several advanced functions, including timed let by and tightness testing, timed CO build-up room tests, integrated magnets, calibration countdown and can even print out serial numbers and next calibration due date on print outs.

The TPI 717R is the upgraded version of TPI's 709R analyser with exclusive features such as timed let by and tightness testing, timed CO build-up room testing and a useful integrated magnet for mounting the analyser to a boiler for hands free use. All TPI analyzers feature quick and simple set up. Fast purge and the ability to perform fuel selection during start up enable tests to be performed quickly without requiring extra set-up time after initial startup. TPI analyzers use the last selected fuel as the default setting. This feature prevents the need toper form fuel selection every time the analyzer is turned on.

TPI 717 makes field sensor replacement simple. Pre-calibrated oxygen and carbon monoxide smart sensors enable users to perform sensor replacement without having to perform calibration. Simply remove the old sensor, install the new sensor, and wait 24 hours for sensor stabilization. Once the 717 is turned on calibration data is automatically transferred to the analyzer.

Features:

  • Easy to operate
  • Fast purge function
  • Measure pressure using differential manometer in mbar, kPa or inH20
  • Backlight LCD screen for use in poor lighting conditions
  • 50 record internal memory
  • Measures carbon monoxide quantities in ambient air
  • Combustion efficiency functions - measure O2, CO, flue temperature and more
  • Tightness/let by and burner pressure testing
  • Differential thermometer with dual K-type thermocouple inputs

Accurately measures:

  • 0-25% volume oxygen (O2)
  • 0-10,000ppm carbon monoxide (CO)
  • Flue temperature

Calculates:

  • CO2
  • CO/CO2 ratio
  • Efficiency

Multi-fuel:

  • Natural gas, LPG, light oil, heavy oil, bituminous coal
  • Anthracite coal, coke, butane, wood (dry), wood (pellets) & bagasse
  • Timed let-by/tightness testing
  • Timed room CO build up testing
  • Flow and return temperature testing
  • Differential pressure measurement
  • Easy log for 50 readings or instant print
  • Infra-red output to optional printer
  • Accurately calculates boiler efficiency
  • Instrument serial number and calibration due date on test report print

 

Choose Your Analyser 709R 717R 716
10,000 ppm CO Sensor * * *
Long Life O2 Sensor * * *
NO & Calculated Nox     Optional
Calculated CO2 Readings * * *
Calculated Ration Readings * * *
Calculated Efficiency Readings * * *
Differential Temperature * * *
Differential Manometer * * *
Temperature Sampling Probe * * *
In-Line Water Trap Bowl Filter * * *
In-Line Mini Pump Protection Filter * * *
Protective Rubber Boot * * *
Re-Chargeable NiMH Battery * * *
Soft Carry Case * * *
Diagnostic Software * * *
Readings Output to (Optional) IR Printer * * *
6 Year Warranty* * * *
Combustible Gas Leak Detector     Optional
Option of Company Details on Header of IR Print-Outs     *
CO Build Up Test Software   * *
Tightness Test Software   * *
Data Logging Facility     *
Data Transfer c/w Software to PC/Laptop/PDA by USB     *
Data Transfer to PC/Laptop/PDA by Bluetooth     Optional
Graphical 4 or 8 Line Display     *
Menu Driven User Interface     *
Calibration Due Countdown   * *
Quick Start Menu     *

 

Choose Your Kit Kit 1 Kit 2 Kit 3 Kit 4 Kit 5 Kit 1 Oil
A740 IR Printer * * * * * *
CK21M Pipe Clamps (Pair)   * * * *  
CPA1 Probe Kit     *   *  
719 Gas Sniffer (Plug in Gas Sniffer for 716 Model)       * *  
Smoke Pump & Oil Filter           *

 

Whats Included?

  • TPI 717 Flue Gas Analyser
  • Rubber Boot
  • Soft Carrying Case
  • Flue Sampling Probe
  • In-Line Filter Assembly on Flue Probe
  • Temperature Probe
  • Mini Pump Protection Filter Assembly + Spare Filters
  • Removable Exhaust Spigot
  • Instruction Manual

Kit 5 also includes:

  • TPI A740 IR Printer
  • 2 x Pipe Clamp Temperature Probes
  • CPA1 Cooker Probe Kit
  • TPI 719 Gas Sniffer

Specifications:

Instrument
 Operating Temperature Range  -10˚C to +50˚C
 Battery / Battery Life  Rechargeable Ni-MH / > 6 Hours
 Charger Input Voltage  115V or 230V : 50/60 Hz AC
 Fuels  Natural Gas, LPG, Light Oil, Heavy Oil, Bituminous Coal, Anthracite Coal,
 Coke, Butane Wood (Dry), Bagasse, Wood Pellet
 Pressure Ranges  mbar, kPa & inH2O
 Display  Backlit LCD
 Data Storage  50 sets of readings
 Time and Date  24 Hour Real Time Clock
 Dimensions  200mm x 90mm x 60mm
 Weight  500g
 Casing  Rubber Boot as Standard
 Switch Off  Failsafe
 Exhaust  Safety Spigot
 Conforms to  BS7927 (and the draft BS7967)

 

 Flue Temperature Probe
 Construction  Pistol Grip with Stainless Steel Shaft
 Hose Length  2500mm
 Insertion Length  200mm
 'K' Type Thermocouple Accuracy  +/- 0.3%, +/- 1˚C
 Maximum Temperature  800°C

 

 Gases  Range  Resolution  Accuracy
 Oxygen  0-25%  0.1%  +/- 0.3%
 Carbon Monoxide  0-10,000 ppm  1 ppm  <20 ppm : +/- 3 ppm
 >100 ppm : +/- 5 %
 Carbon Dioxide (calculated)  0-25%  0.1%  +/- 0.3%
 Combustion Efficiency  0-100%  0.1%

 

 Pressure Measurement
 Selectable Ranges  mbar, kPa and inH2O
 Range  - 150 mbar to + 150 mbar
 Resolution  0.01 mbar & 0.1 mbar
 Accuracy  +/- 0.5% fsd

 

 Temperature Measurement
 Input Type  K-Type thermocouple
 Range  -58°F to 1832°F (-50°C to 1000°C)*
 Resolution  1°F (1°C)
 Accuracy  +/- (0.3% of rdg + 2°F) or +/- (0.3% of rdg + 1°C)
 * The thermocouple supplied (GK11M) has the ability to measure temperatures in the -50°F to 950°F range.
  The 712 accepts industry standard K-type thermocouple probes with sub-mini connectors.
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account