Fluke a3001 FC Wireless iFlex AC Current Clamp Kit

£339.95

£407.94

SKU
FLU/FLK-A3001FC KIT
  • Everything you'll need to create a wireless network for measuring AC current
  • Continuity, resistance, diode, capacitance and frequency measurements
  • Probe bends around even the most difficult of conductors
  • Measurements of AC current up to 2500A
pdf
(Size: 146.8 KB)
pdf
(Size: 2.8 MB)
More Information
Warranty 1 year
Price Match No

Fluke a3001 FC Wireless iFlex AC Current Clamp Kit 

Connect the a3001 FC Wireless AC Current Module and flexible current probe to your test point, and view the results up to 20 metres away on the 3000 FC Wireless Digital Multimeter.

You'll save time, with less run-around collecting multiple measurements.  Use multiple modules for measurements on three-phase systems, as a stand-alone measurement tool or combine with other Fluke Connect modules as a system for multiple measurements.

From short distances, you can even view readings from modules through closed electrical  Fluke a3001 FC Wireless iFlex AC Current Clamp Kit provides measurement of many common electrical parameters.

Fluke 3000 FC Wireless Multimeter:

  • AC/DC voltage measurements
  • AC/DC current measurements
  • Continuity, resistance, diode, capacitance and frequency measurements
  • MIN/MAX recording
  • CAT III 1000V and CAT IV 600V safety rated
  • IP54 ingress protection
  • Wireless connectivity with other Fluke FC series compatible instruments/devices


Fluke a3001 FC Wireless iFlex AC:

  • Measurements of AC current up to 2500A
  • Suitable for use individually as a clamp meter or can wirelessly interface with other Fluke FC testing tools
  • Logging function stores up to 65000 measurements directly on the module
  • Inrush function
  • Bendable probe

Fluke 3000 FC Wireless Multimeter Specifications:

AC Voltage
Range Resolution Accuracy 
    45Hz to 500Hz 500Hz to 1KHz
600.0mV 0.1mV 1.0% + 3 2.0% + 3
6.000V 0.001V
60.00V 0.01V
600.0V 0.1V
1000V 1V
Note

All AC voltage ranges are specified from 1% of range to 100% of range.
Crest factor of ≤ 3 at full scale up to 500V, decreasing linearly to crest factor < 1.5 at 1000V
For non sinusoidal waveforms, add ± (2% of reading + 2% of full scale) typical, for crest factor up to 3.
Do not exceed 10V Hz

DC Voltage, Continuity, Resistance, Diode Test and Capacitance
Function Range Resolution Accuracy
mV 600.0mV 0.1mV 0.09% + 2
V 6.000V 0.001V 0.09% + 2
60.00V 0.01V
600.0V 0.1V
1000V 1V 0.15% + 2
Ω 600.0Ω 0.1Ω 0.5% + 1
6.000kΩ 0.001kΩ
60.00kΩ 0.01kΩ
60.00kΩ 0.1kΩ
600.0kΩ 0.001MΩ
50.00MΩ 0.01MΩ 1.5% + 3
Diode Test 2.000V 0.001V 1% + 2
μF 1000nF 1nF 10% typical
10.00μF 0.01μF
100.0μF 0.1μF
9999μF 1μF
Note In the 9999μF range for measurements to 1000μF, the measurement accuracy is 1.2% + 2
AC and DC Current
Function Range Resolution Accuracy
mA AC (45Hz to 1KHz) 60.00mA 0.01mA 1.5% + 3
400.0mA  
mA DC 60.00mA 0.01mA 0.5% + 3
  400.0mA 0.1mA
Note All AC current ranges are specified from 5% of range to 100% of range
Input burden voltage (typical): 400mA input 2mV/mA
400.0mA accuracy specified up to 600mA overload
Frequency
Range Resolution Accuracy
99.99Hz 0.01Hz 0.1% + 1
999.9Hz 0.1Hz
9.999kHz 0.001Hz
99.99kHz 0.01kHz
Input Characteristics
Function Overload Protection Input Impedance (Nominal) Common Mode Rejection Ratio (1kΩ Unbalance) Normal Mode Rejection
1100V rms >10MΩ < 100pF > 120 dB at dc, 50 Hz or 60 Hz > 60 dB at 50 Hz or 60 Hz
1100V rms >10MΩ < 100pF > 60 dB, dc to 60 Hz  
1100V rms >10MΩ < 100pF > 120 dB at dc, 50 Hz or 60 Hz > 60 dB at 50 Hz or 60 Hz
Open Circuit Test Voltage Full Scale Voltage Typical Short Circuit Current
1100V rms <2.7V DC To 6MΩ: <0.7VDC
50MΩ: <0.9V DC
<350mA
1100V rms <2.7V DC 2.000V DC <1.1mA
Function Overload Protection  Overload
mA Fused, 44/100A, 1000V FAST Fuse   600mA overload for 2 minutes maximum, 10 minutes rest minimum
MIN/MAX Recording
Function Accuracy
DC Functions The specified accuracy of the measurement function ± 12 counts for changes > 350 ms in duration.
AC Functions The specified accuracy of the measurement function ± 40 counts for changes > 900 ms in duration.
General Specifications
Maximum Voltage Between Any Terminal and Earth Ground 1000V DC or AC RMS
Ω Fuse Protection From A Inputs 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Display (LCD) Update rate: 4/sec
Votls, amps, ohms: 6000 counts
Frequency: 10,000 counts
Capacitance: 1,000 counts
Battery Type 3 x AA alkaline batteries, NEDA 15A IEC LR6
Battery Life 250 hours maximum
RF Communications 2.4GHZ ISM Band
RF Communication Range Open air, unobstructed: Up to 20m
Obstructed, sheetrock wall: Up to 6.5m
Obstructed, concrete wall, or steel electrical enclosure: Up to 3.5m
Temperature Operating: -10 °C to 50 °C
Storage: -40 °C to 60 °C
Temperature Coefficient 0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Relative Humidity 0 % to 90 % (0 °C to 35 °C), 0 % to 75 % (35 °C to 40 °C), 0 % to 45 % (40 °C to 50 °C)
Altitude Operating: 2,000 m
Storage: 12,000 m
Electromagnetic Compatability EMI, RFI, EMC, RF EN 61326-1:2006, EN 61326-2-2:2006. ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249,
FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE
Safety Compliance ANSI/ISA 61010-1 / (82.02.01): 3rd edition
CAN/CSA-C22.2 No 61010-1-12: 3rd edition
UL 61010-1: 3rd edition
IEC/EN 61010-1:2010
Certifications CSA, FCC, CE
Ingress Protection (IP) Rating IP54
Pollution Degree 2
Size (H x W x L) 4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in)
Weight 340g (12oz)

 

Fluke a3001 FC Technical Specifications:

Range 0.5A to 2500A AC
Resolution 0.1A
Accuracy 3% ± 5 digits (5Hz to 500Hz)
Crest Factor (50Hz/60Hz) 3.0 at 1100A
2.5 at 1400A
1.42 at 2500A
add 2% for C.F > 2
LCD w/Backlight 3 1/2 digits
Log Rate/Interval 1 sec minimum/adjustable by PC or front panel
Battery Type 2 AA, NEDA 15A, IEC LR6
Battery Life 400 hours
Memory Record up to 65000 readings
RF Communications 2.4GHZ ISM band
RF Communication Range Open Air, Unobsctructed: Up to 20m
Obstructed, Sheetrock Wall: Up to 6.5m
Obstructed, Concrete Wall or Steel Electrical Enclosure: Up to 3.5m
Operating Temperature -10 to 50°C
Storage Temperature -40 to 60°C
Temperature Coefficient Add 0.1X (specified accuracy) / °C (<18°C or >28°C)
Operating Humidity 90% at 35°C
75% at 40°C
45% at 50°C
Altitude Operating: 2000m
Storage: 12000m
EMC EN 61326-2006
Safety Compliance IEC 61010-1, 600V CAT IV/ 1000V CAT III, 3rd edition
Safety Rating CAT IV 600V, CAT III 1000V
Certifications CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
Ingress Protection (IP) Rating IP42
Pollution Degree 2
Jaw Opening 25.4cm (10in) coil
Size (H x W x D) 16.5cm x 6.35cm x 1.4cm (6.5in x 2.5in x 1.4in)
Weight .22kg (8 oz)

 

What's Included?

  • Fluke 3000 FC Series Wireless Digital Multimeter
  • Fluke a3001 FC Wireless iFlex AC Current Module
  • TL175 Test Leads
  • AC175 Alligator Clips
  • iFlex i2500-10 Flexible Current Probe
Ask Your Question
Jot us a note and we’ll get back to you as quickly as possible.
Write Your Own Review
You're reviewing:Fluke a3001 FC Wireless iFlex AC Current Clamp Kit
Your Rating