- Fluke’s flagship multifunction tester with Fluke Connect
- Automatically carries out 5 required installation tests in one sequence
- Insulation PreTest prevents potentially serious and costly mistakes
- FlukeCloud allows you to share your results
- Test smooth DC sensitive RCDs (Type B/B+)
Warranty | 1 year |
---|---|
Price Match | Yes |
-
Fluke 115 Digital Multimeter<p><strong>Fluke 115 Digital Multimeter</strong></p> <p><strong><img src="{{media url="wysiwyg/T4L_banner_DMM_range115.jpg"}}" alt="Fluke 115 Banner" /></strong></p> <p>The Fluke 115 is designed for everyday use as a general purpose digital multimeter for electrical testing. Featuring AC/DC voltage to 600V and AC/DC current to 10A (10A overload for 30-seconds) the Fluke 115 is perfect for quick verifications and for field service engineers who require and affordable, feature packed multimeter. The 115 is powered by a single 9V battery, with an estimated 400 hours battery life (without backlight).</p> <p>Capacitance, frequency, continuity and resistance measurement are also features of the 115, making it a truly versatile tool that fits in the palm of your hand, weighing only 550g. The user can also record signal fluctuations with the MIN/MAX/Average feature.</p> <p><strong>Features at a glance...</strong></p> <ul> <li>AC/DC voltage measurement to 600V</li> <li>True RMS AC/DC current measurement to 10A</li> <li>Compact, lightweight and designed for single handed operation</li> <li>Large backlit easy to read display</li> <li>Simple rotary dial and button operation</li> <li>Built in LoZ capacitance to avoid misleading ghost voltages</li> <li>Continuity (with buzzer) Resistance, Frequency, Capacitance and Diode testing</li> <li>Estimated 400 hour battery life (without backlight)</li> </ul> <p><strong>Fluke multimeter comparison table</strong></p> <table style="width: 100%;" border="1" cellspacing="8" cellpadding="8"> <tbody> <tr> <td style="text-align: center;"><strong>Models</strong></td> <td style="text-align: center;"><strong>113</strong></td> <td style="text-align: center;"><strong>114</strong></td> <td style="text-align: center;"><strong>115</strong></td> <td style="text-align: center;"><strong>116</strong></td> <td style="text-align: center;"><strong>117</strong></td> </tr> <tr> <td style="background-color: #c8cfce; text-align: left;" colspan="6"><strong>Features</strong></td> </tr> <tr> <td style="text-align: center;">Counts</td> <td style="text-align: center;">6000</td> <td style="text-align: center;">6000</td> <td style="text-align: center;">6000</td> <td style="text-align: center;">6000</td> <td style="text-align: center;">6000</td> </tr> <tr> <td style="text-align: center;">True-rms readings</td> <td style="text-align: center;">AC</td> <td style="text-align: center;">AC</td> <td style="text-align: center;">AC</td> <td style="text-align: center;">AC</td> <td style="text-align: center;">AC</td> </tr> <tr> <td style="text-align: center;">Auto/manual ranging</td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> </tr> <tr> <td style="background-color: #c8cfce; text-align: left;" colspan="6"><strong>Measurements</strong></td> </tr> <tr> <td style="text-align: center;">Voltage AC/DC</td> <td style="text-align: center;">600V</td> <td style="text-align: center;">600V</td> <td style="text-align: center;">600V</td> <td style="text-align: center;">600V</td> <td style="text-align: center;">600V</td> </tr> <tr> <td style="text-align: center;">Current AC/DC</td> <td style="text-align: center;"> </td> <td style="text-align: center;"> </td> <td style="text-align: center;">10A</td> <td style="text-align: center;">600μA</td> <td style="text-align: center;">10A</td> </tr> <tr> <td style="text-align: center;">Resistance</td> <td style="text-align: center;">60kΩ</td> <td style="text-align: center;">40MΩ</td> <td style="text-align: center;">40MΩ</td> <td style="text-align: center;">40MΩ</td> <td style="text-align: center;">40MΩ</td> </tr> <tr> <td style="text-align: center;">Frequency</td> <td style="text-align: center;"> </td> <td style="text-align: center;"> </td> <td style="text-align: center;">100kHz</td> <td style="text-align: center;">100kHz</td> <td style="text-align: center;">100KHz</td> </tr> <tr> <td style="text-align: center;">Temperature</td> <td style="text-align: center;"> </td> <td style="text-align: center;"> </td> <td style="text-align: center;"> </td> <td style="text-align: center;">+ 400 °C</td> <td style="text-align: center;"> </td> </tr> <tr> <td style="text-align: center;">Continuity/diode test</td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> </tr> <tr> <td style="text-align: center;">VoltAlert, non contact voltage detection</td> <td style="text-align: center;"> </td> <td style="text-align: center;"> </td> <td style="text-align: center;"> </td> <td style="text-align: center;"> </td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> </tr> <tr> <td style="text-align: center;">VCHEK</td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> <td style="text-align: center;"> </td> <td style="text-align: center;"> </td> <td style="text-align: center;"> </td> <td style="text-align: center;"> </td> </tr> <tr> <td style="text-align: center;">LoZ: low input impedance</td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> <td style="text-align: center;"> </td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> </tr> <tr> <td style="text-align: center;">Microamps</td> <td style="text-align: center;"> </td> <td style="text-align: center;"> </td> <td style="text-align: center;"> </td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> <td style="text-align: center;"> </td> </tr> <tr> <td style="background-color: #c8cfce; text-align: left;" colspan="6"><strong>Display</strong></td> </tr> <tr> <td style="text-align: center;">Analog bargraph</td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> </tr> <tr> <td style="text-align: center;">Backlight</td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> </tr> <tr> <td style="background-color: #c8cfce; text-align: left;" colspan="6"><strong>Diagnostics and data</strong></td> </tr> <tr> <td style="text-align: center;">Min/Max recording</td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> </tr> <tr> <td style="text-align: center;">Display Hold</td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> </tr> <tr> <td style="background-color: #c8cfce; text-align: left;" colspan="6"><strong>Other Features</strong></td> </tr> <tr> <td style="text-align: center;">Automatic selection, AC/DC volts</td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> <td style="text-align: center;"> </td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> </tr> <tr> <td style="text-align: center;">Closed case calibration</td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> </tr> <tr> <td style="text-align: center;">Seperate battery/fuse access</td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> </tr> <tr> <td style="text-align: center;">Automatic Power Off</td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> </tr> <tr> <td style="text-align: center;">Low Battery Indication</td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> <td style="text-align: center;"><span style="font-size: large;">•</span></td> </tr> <tr> <td style="text-align: center;">Operating temperature range</td> <td style="text-align: center;">-10 °C, +50 °C</td> <td style="text-align: center;">-10 °C, +50 °C</td> <td style="text-align: center;">-10 °C, +50 °C</td> <td style="text-align: center;">-10 °C, +50 °C</td> <td style="text-align: center;">-10 °C, +50 °C</td> </tr> <tr> <td style="background-color: #c8cfce; text-align: left;" colspan="6"><strong>Warranty and Electrical Safety</strong></td> </tr> <tr> <td style="text-align: center;">Warranty (years)</td> <td style="text-align: center;">3</td> <td style="text-align: center;">3</td> <td style="text-align: center;">3</td> <td style="text-align: center;">3</td> <td style="text-align: center;">3</td> </tr> <tr> <td style="text-align: center;">IP Rating</td> <td style="text-align: center;">IP42</td> <td style="text-align: center;">IP42</td> <td style="text-align: center;">IP42</td> <td style="text-align: center;">IP42</td> <td style="text-align: center;">IP42</td> </tr> <tr> <td style="text-align: center;">Safety rating (EN 61010) CAT III</td> <td style="text-align: center;"> </td> <td style="text-align: center;">600V</td> <td style="text-align: center;">600V</td> <td style="text-align: center;">600V</td> <td style="text-align: center;">600V</td> </tr> <tr> <td style="text-align: center;">Safety rating (EN 61010) CAT IV</td> <td style="text-align: center;">600V</td> <td style="text-align: center;"> </td> <td style="text-align: center;"> </td> <td style="text-align: center;"> </td> <td style="text-align: center;"> </td> </tr> </tbody> </table> <p> </p> <p><strong>Fluke says...</strong></p> <ul> <li>Best for: Electronic and field service applications</li> <li>Electronic troubleshooting: Troubleshoot a wide variety of measurement parameters, including frequency and capacitance.</li> </ul> <p><strong>The Fluke 115 features in the Fluke 11X mutlimeter range.</strong></p> <ul> <li><strong><a title="Fluke 116" href="https://test4less.co.uk/fluke-116-hvac-multimeter.html">Fluke 116</a></strong>: HVAC multimeter with temperature measurement and micro amps to test flame sensors</li> <li><strong><a title="Fluke 117" href="https://test4less.co.uk/fluke-117-electricians-multimeter.html">Fluke 117</a></strong>: High spec multimeter with integrated non-contact voltage detection</li> </ul> <p>Test4less are an approved Fluke distributor and service centre. We can calibrate your new Fluke 114 prior to dispatch, if required and also when you require recalibration. Our lab calibrates over 49,000 test instruments every year both new and old.</p> <p><strong>What's Included?</strong></p> <ul> <li>Fluke 115 Digital Multimeter</li> <li>Holster</li> <li>Installed 9V Battery</li> <li>4mm Silicone Test Lead Set</li> <li>User Manual</li> </ul>
-
Fluke DMS Complete Pro Software<p><strong> Fluke DMS Complete Pro Software</strong></p> <p>Fluke DMS (data management software) Complete / Professional is a software package for data recording and administration of test results for electrical installation (MFT 1663 and MFT 1664) or portable appliance testing (PAT 6500-2).</p> <p><strong>Features:</strong></p> <ul> <li>Simple to use</li> <li>Print off test reports and certificates</li> <li>Compatible with Fluke 1663 and 1664 installation testers</li> <li>Compatible with Fluke 6500-2 PAT Tester</li> </ul> <p><strong>What's Included?</strong></p> <ul> <li>Fluke DMS Complete Pro Software</li> </ul>
Details
Fluke 1664FC 18th Edition Multifunction Installation Tester with Fluke Connect
The Fluke 1664 is the top of the range multifunction tester from Fluke. Packed full of new features to help make testing safe, faster and much more convenient.
What’s NEW on the Fluke 1664.
Auto test sequence
Completes 5 required installation test in one sequence with a single touch of the test button, ensuring compliance with local installation regulations. Auto Test reduces the number of manual connections, decreases the chance of making errors and reduces test time by 40% when compared to previous Fluke models.
Insulation Pre test
The Fluke 1664 prevents the user from making potentially serious and costly mistakes when carrying out an insulation test. If the tester detects that an appliance is connected to the system under test, then the insulation test will not be stopped before damage is caused. A visual warning is also displayed. This is a unique feature of the Fluke 1664 which is not found on any other MFT.
Fluke Connect
Fluke Connect available free to download on iOS and Android, allows you to easily store measurement results on the app. You can also easily email your recorded measurements to colleagues for them to view even when they are not on site (Wi-Fi or mobile signal required).
FlukeCloud
All your data and test results stored via FlukeCloud are ready for easy access using your smart phone or tablet, anytime anywhere. You can also import the data into Fluke DMS to process and generate certificates.
NEW insulation test at L-N, L-PE and N-PE inputs
NEW continuity tests at L-N, L-PE and N-PE inputs
Other Features
- The 1664’s large, backlit, dual display allows PEFC/ PSC and loop impedance measurements to be displayed simultaneously.
- The 1664 also has a time-saving auto-null feature that, by simply touching the test leads together and pressing the zero button, measures and stores the test lead resistance, even after the instrument has been switched off. A zero adaptor is also included.
- Testing particularly sensitive equipment such as telecommunications installations, fire alarm systems, emergency lighting, intruder alarms, sound systems or conductivity of floors can be carried out using the 1664 as it has the required 50V and 100V insulation test ranges.
- To simplify RCD testing, the 1660 Series models have an auto mode for measuring RCD tripping time in which six tests are automatically carried out in sequence, removing the requirement for the user to keep returning to the installation tester after resetting a tripped RCD. The instrument senses when the RCD has been reset and initiates the next test in the sequence automatically. The 1663 and 1664 also have internal memory for storing results for later recall, as well as a temporary memory that allows you to cycle through results straight after the tests. The 1662, 1663 and 1664 can also measure RCD tripping current (commonly referred to as a ramp test) by gradually increasing an applied current until the RCD trips.
- Autotest to test line/loop impedance, RCD trip current / trip time, insulation tests with a single connection and button press.
- Additional high current loop mode. Faster measurements compared to loop tests with non-trip mode for RCDs.
- Z-max memory for loop tests – easy evaluation of the highest loop test value.
- Unique zero adapter for fast, always reliable and accurate test lead and mains cord compensation.
- Fast voltage measurement between L-N, L-PE and N-PE using the mains cord. No need to change measurement connections.
- Measure RCD trip current & trip time in parallel (RCD type AC and A).
- Two measurements at once and a dual display. PEFC or PSC and loop impedance are measured and displayed in parallel.
- Ring testing – select the required input sockets with soft keys – no need to exchange test leads.
- Automatic test start for Loop & RCD tests – as soon as mains voltage is stable it starts testing.
- Earth Volt Touchpad detects raised earth voltages >50 V, indicating potential dangerous situations.
- Supplied with the Fluke SureGrip™ test leads and clips which gives the user a comfortable, reliable grip and consistent results.
- Rotary dial knob indicates clearly which function is selected, all in one spot with no complex multi-level menus.
- Large display with backlight, clear symbols and with exceptionally wide viewing angle for easy and safe readings.
- PASS/FAIL indication for RCD test results.
- Variable RCD current mode for customized settings.
- Loop & line resistance with mΩ resolution.
- Test smooth dc sensitive RCDs (Type B).
- Extended memory with 3 layers.
- Use continuity test currents to measure motor windings.
- Withstands a drop of 1 meter.
- Compact, lightweight (less than 1.3 kg) and padded neck-strap to free your hands for all day testing.
Compare Fluke 1660 Series | 1662 | 1663 | 1664 FC |
Insulation-PreTest safety function NEW | ● | ||
Insulation test at L-N, L-PE, N-PE inputs NEW | ● | ||
Auto Test sequence NEW Performs line/loop impedance, RCD trip current/trip time and insulation tests in one go |
● | ||
Loop and line resistance—mΩ resolution | ● | ||
Continuity test at L-N, L-PE, N-PE inputs NEW | ● | ● | |
Continuity test selectable at 250mA/10mA with Auto polarity swap | ● | ● | ● |
Test smooth dc sensitive RCDs (Type B/B+) | ● | ● | |
Earth resistance | ● | ● | |
Voltage measurement TRMS (ac and dc) and frequency | ● | ● | ● |
Wiring polarity checker, detects broken PE and N wires | ● | ● | ● |
Insulation resistance | ● | ● | ● |
Continuity and resistance | ● | ● | ● |
Measure motor windings with continuity test (@ 10 mA) | ● | ● | ● |
Loop and line resistance | ● | ● | ● |
Prospective Earth Fault Current (PEFC/IK) | ● | ● | ● |
Prospective Short-Circuit Current (PSC/IK) | ● | ● | ● |
RCD trip time | ● | ● | ● |
RCD trip current (ramp test) | ● | ● | ● |
Measures trip time (ramp) and current for RCD type A and AC in one test | ● | ● | ● |
RCD variable test current | ● | ● | ● |
Automatic RCD test sequence | ● | ● | ● |
Phase sequence test | ● | ● | ● |
Other Features | |||
Fluke Connect compatibility NEW | ● | ||
ShareLive™ calling NEW | ● | ||
Fluke Cloud™ storage NEW | ● | ||
On/Off switchable Auto Start for RCD and Looptest NEW | ● | ● | ● |
Self-test | ● | ● | ● |
Illuminated display | ● | ● | ● |
Memory, interface | |||
Z Max memory (for loop tests- easy evaluation of the highest loop test value)NEW | ● | ● | |
Memory 3000 measurements | ● | ● | |
IR-USB and BLE interface (use with optional Fluke DMS software) | IR-USB | IR-USB/BLE | |
Included Accessories | |||
Heavy duty mains cord with single input connector NEW | ● | ● | ● |
Hard case | ● | ● | ● |
Fused test probes | ● | ● | ● |
Remote control probe | ● | ● | ● |
Zero adapter | ● | ● | ● |
Safety Overvoltage CAT III 500 V, CAT IV 300 V | ● | ● | ● |
3 year warranty | ● | ● | ● |
Insulation test voltages : 100V/250V/500V/1000V | ● | ● | |
Insulation test voltages : 50V/100V/250V/500V/1000V | ● |
Test4less 'Bolt On Kit's' include a range of useful accessories and offer a guaranteed saving against buying separately.
What's Included?
- Fluke 1664FC Multifunction Installation Tester with Fluke Connect
- 6x AA (IEC LR6) cell batteries
- C1600 hard carrying case
- Zero adapter
- Heavy duty mains cord
- STD standard test lead set
- C1600 hard carrying case
- Padded carrying and waist strap
- Quick reference guide
- TP165X remote control probe and lead
- User's manual on CD-ROM